Digital Key Switch (490-0535A) Installation Faxback Doc. # 6864 Installation Hints Before installing the Digital Key Switch, make temporary connections between the alarm system and the Digital Key Switch to confirm proper operation. If you have problems, see Faxback document # 6865. Install the Digital Key Switch indoors where it will not be subjected to dust, dirt, or extremes in temperature or humidity. Set the LATCH IN/OUT switch before power is connected to the Digital Key Switch. 1. Select a location on the wall that is next to a wall stud. 2. Using a single-gang electrical box as a template, make a hole just large enough to accept the electrical box. 3. Run the necessary wires from the alarm system to the hole (through attic, walls etc.) and through one of the knock-out plugs in the electrical box. Be sure to leave enough extra wire to allow for connection to the Digital Key Switch. 4. Insert the box into the hole and nail it to the wall stud; the box should be recessed slightly below the surface of the wall. 5. Connect the wires to the Digital Key Switch terminals, as described in the manual. Be sure to avoid stray wires that touch other terminals or the other sides of the box. 6. Carefully push the wires into the box and attach the keyboard portion of the Digital Key Switch to the box using the two supplied screws. 7. Hang the Digital Key Switch cover plate at the top of the Digital Key Switch and secure it at the bottom using the supplied set screw. Note: The cover plate holds in the tamper switch plunger. If the tamper switch is connected to a 24-hour panic/tamper loop on your alarm, the alarm will be tripped if the cover plate is removed, even if the alarm is not armed. (LB/all-7/12/94)