HTX-404 (190-1140) Using Memory Channels Faxback Doc. # 6176 The HTX 404 has 16 memory channels in three groups. * One calling-frequency memory * Three priority-frequency memories * 12 standard memories CHANGING MEMORY OPTIONS You can program each memory with a different frequency offset and subaudible tones. Follow these steps to change the settings for a memory location. 1. Tune to the memory channel. 2. Press F+ M-SET. The HTX-404 displays tF followed by the transmit frequency. 3. Rotate TUNE to change the transmit frequency. 4. Press DOWN ARROW SC to set the transmit subaudible tone frequency. The HTX-404 displays tc followed by the transmit subaudible tone frequency. 5. Rotate TUNE to change the transmit subaudible tone frequency. Set the option to oFF to not transmit a subaudible tone 6. Press DOWN ARROW SC to set the receive subaudible tone frequency. The HTX-404 displays rC followed by the receive subaudible tone frequency. 7. Rotate TUNE to change the receive subaudible tone frequency. Set the option to OFF to not require a receive subaudible tone. 8. Press PTT to save the settings in the selected memory channel. Using the Calling-Frequency Memory The calling frequency memory stores a single frequency you can quickly tune to at any time. Follow these steps to save a frequency in the calling frequency memory. 1. Press VF. 2. Tune to the frequency you want to save. 3. Set the offset to the desired setting (+,-, or off) by pressing F + +/-. 4. Turn on the tone-squelch option by pressing F + T-SQL, if necessary. 5. Press CA. 6. Press and hold down F+ M-WR for at least 1 second. The HTX-404 stores the tuned frequency, the frequency offset direction, and the setting of the tone squelch option. If you need to set a frequency offset other than the default 5 MHz separation, or if you need to change the tone-squelch frequency, see "Changing Memory Options" above. To use the calling-frequency memory, press CA at any time. The HTX-404 immediately moves to the calling frequency. To return to the previous settings, press CA again. Or press VF to return to the last manually-tuned frequency setting. Using the Priority-Frequency Memories The HTX-404 has three priority-frequency memories. The HTX-404 can periodically scan these frequencies during manual, calling-frequency memory, or standard memory operation. Follow these steps to store frequencies in the priority-frequency memories. 1. Press VF and tune to the frequency you want to save. 2. Press F and rotate TUNE until either P1, P2, or P3 appears to the left of the tuned frequency. 3. Set the offset to the desired setting (+,-, or off) and turn on the tone-squelch option, if necessary. 4. Press F + M-WR for at least 1 second to store the tuned frequency in the selected priority-frequency memory. 5. To change the frequency separation or subaudible tones, see "Changing Memory Options" above. Each priority frequency memory can have different settings. To set the HTX-404 to a priority frequency, press PR. Then do one of the following to select one of the three memories: * Rotate TUNE * Press UP ARROW SC or DOWN ARROW SC * Press 1, 2, or 3 To have the scanner check the priority-frequency memories for activity, press VF. Then press F+ P-SC. for at least 1 second. The HTX-404 checks the priority-frequency memories every 4 seconds. To continuously scan the three priority frequency memories, press PR. Then press and hold down UP ARROW SC or DOWN ARROW SC for at least 1 second. Note: You must store more than one priority frequency in memory to continuously scan priority-frequency memories. Using the Standard Memories Your HTX-404 has 12 standard memories into which you can store frequently- accessed frequencies for quick access. Follow these steps to store frequencies into standard memories. 1. Press VF and tune to a frequency you want to store. 2. Press F and rotate TUNE until the memory number to the left of the frequency display shows the standard memory you want to store the frequency into. 3. Set the offset to the desired setting (+,-, or off) and turn on the tone-squelch option, if necessary. 4. Press F+M-WR for at least 1 second to store the tuned frequency in the selected priority-frequency memory. 5. To change the frequency separation or subaudible tones, see "Changing Memory Options" above. Each priority frequency memory can have different settings. To set the HTX-404 to a priority frequency, press PR. Then do one of the following to select one of the three memories: * Rotate TUNE * Press UP ARROW SC or DOWN ARROW SC * Press 1, 2, or 3 To have the scanner check the priority-frequency memories for activity, press VF. Then press F + P-SC for at least 1 second. The HTX-404 checks the priority-frequency memories every 4 seconds. To continuously scan the three priority frequency memories, press PR. Then press and hold down UP ARROW SC or DOWN ARROW SC for at least 1 second. Note: You must store more than one priority frequency in memory to continuously scan priority-frequency memories. Using the Standard Memories Your HTX-404 has 12 standard memories into which you can store frequently -accessed frequencies for quick access. Follow these steps to store frequencies into standard memories. 1. Press VF and tune to a frequency you want to store. 2. Press F and rotate TUNE until the memory number to the left of the frequency display shown the standard memory you want to store the frequency into. 3. Set the offset to the desired setting (+,-, or off) and turn on the tone-squelch option, if necessary. 4. Press F + M-WR for at least 1 second to store the tuned frequency into the selected standard memory. 5. To change the frequency separation or subaudible tones, see "Changing Memory Options." Each memory location can have different settings. To set the HTX-404 to a standard memory, press MR. Then rotate TUNE or press UP ARROW SC or DOWN ARROW SC to select one of the 12 memories. To continuously scan standard memories, press MR. Then press and hold down UP ARROW SC or DOWN ARROW SC for at least 1 second. Note: The HTX-404 stops scanning according to the scan options you have set. Clearing Memories Follow these steps to clear a memory. 1. Press PR or MR and select the number for the memory you want to clear. 2. Press F+M-CLR to clear the settings stored in the current memory. Note: You cannot clear Standard Memory 1 or the calling-Frequency memory. You can only change the memory settings for these memories. Moving a Memory Channel to the Manual Mode Follow these steps to quickly move a frequency from a memory channel to the manual (VFO) mode. 1. Select the memory channel. 2. Press F + M > VFO All settings for the selected memory move to the VFO mode. REVIEWING PROGRAMMED OPTIONS Follow these steps to view the transmit frequency and the subaudible transmit and receive tone settings for a memory or the directly tuned frequency. 1. Press CA, PR, MR or VF and select the memory or frequency you want to check. 2. If you want to check the subaudible tone settings, press F + T-SQL so T-SQL appears on the display. 3. Press and hold M (located above PTT). The HTX-404's squelch opens, and the display shows the transmit frequency for about 1 second, followed by the subaudible transmit tone and the subaudible receive tone. (RLR-02-25-94)