FaxModem/V.42bis (250-3028) Switches Faxback Doc. # 3292 DIP SWITCH DIP SWITCH FUNCTION AT COMMAND TO SET EQUIVALENT SETTING NON-VOLATILE MEMORY 1 UP (Default) Modem Follows DTR AT&D2&WO&Y0 DOWN Modem Ignores DTR AT&DO&WO&YO 2 UP (Default) Verbal Result Codes ATV1&WO&YO DOWN Numeric Result Codes ATVO&WO&YO 3 UP (Default) Result Codes Disabled ATQ1&WO&YO DOWN Result Codes Enabled ATQO&WO&YO 4 UP (Default) In Local Command State, ATE1&WO&YO Echo Characters DOWN IN Local Command State, ATEO&WO&YO Do Not Echo Characters 5 UP (Default) Auto-answer On ATSO=1&WO&YO DOWN Auto-Answer Off ATSO=0&WO&YO 6 UP (Default) DCD Follows Carrier AT&C1&WO&YO DOWN Forces DCD Always On AT&CO&WO&YO If you ever want to switch ALL of the settings back to the HAYES default configuration (not the FACTORY default configuration), use the command: AT&F (enter) (br/all-11/3/94)